Specification of Annular BOP
|
Model |
Bore (in.) |
Working Pressure (MPa/psi) |
Strength Pressure Testing (MPa/psi) |
Hydraulic Control Pressure (MPa/psi) |
Close Volume (l) |
Open Volume (l) |
Dimensions (mm) |
Total Weight (For Reference) (kg) |
|||
|
A |
B |
C |
D |
||||||||
|
FHZ18-21 |
7 1/6 |
21/3000 |
42/6000 |
≤10.5 /1500 |
13.9 |
11.2 |
800 |
926 |
900 |
983 |
1927 |
|
FHZ18-35 |
35/5000 |
70/10000 |
13.9 |
11.2 |
800 |
954 |
900 |
1011 |
1943 |
||
|
FHZ18-70 |
70/10000 |
105/15000 |
36 |
27 |
1200 |
1250 |
1490 |
|
6293 |
||
|
FHZ35-70 |
13 5/8 |
70/10000 |
105/15000 |
116 |
117 |
1554 |
1742 |
1814 |
|
15190 |
|
|
FHZ54-14 |
21 1/4 |
14/2000 |
21/3000 |
95.3 |
94.5 |
1380 |
1437 |
1512 |
|
7660 |
|
Specification of Ram BOP
|
Model |
Bore (in.) |
Working Pressure (MPa/psi) |
Strength Pressure Testing (MPa/psi) |
Hydraulic Control Pressure (MPa/psi) |
Piston Bore (mm) |
Open Volume (l) |
Close Volume (l) |
Locking Type |
Total Weight (kg) (For Reference) |
Dimensions (mm) |
|||
|
L |
W |
H |
Top |
||||||||||
|
FZ23-35 |
9 |
35/5000 |
70/10000 |
8.4-10.5/ 1200-1500 |
220 |
2×4.4 |
2×5 |
Manual |
1735 |
2027 |
760 |
560 |
Studded |
|
2FZ23-35 |
4×4.4 |
4×5 |
2912 |
2027 |
760 |
782 |
Studded |
||||||
|
FZ28-35 |
11 |
220 |
2×5.15 |
2×5.9 |
2260 |
2110 |
780 |
660 |
Studded |
||||
|
2FZ28-35 |
4×5.15 |
4×5.9 |
4250 |
2110 |
780 |
830 |
Studded |
||||||
|
FZ35-35 |
13 5/8 |
250 |
2×8.25 |
2×8.95 |
4786 |
2400 |
920 |
710 |
Studded |
||||
|
2FZ35-35 |
4×8.25 |
4×8.25 |
6150 |
2400 |
920 |
1360 |
Flanged |
||||||
|
FZ23-70 |
9 |
70/10000 |
105/15000 |
250 |
2×5.38 |
2×6.08 |
3350 |
1958 |
915 |
925 |
Flanged |
||
|
2FZ23-70 |
4×5.38 |
4×6.08 |
6080 |
1958 |
915 |
1345 |
Flanged |
||||||
|
FZ28-70 |
11 |
250 |
2×7 |
2×7.7 |
4870 |
2250 |
1020 |
1040 |
Flanged |
||||
|
2FZ28-70 |
4×7 |
4×7.7 |
7730 |
2250 |
1020 |
1470 |
Flanged |
||||||
|
FZ35-70 |
13 5/8 |
340 |
2×14.7 |
2×16.6 |
6377 |
2670 |
1240 |
960 |
Studded |
||||
|
2FZ35-70 |
4×14.7 |
4×16.6 |
11950 |
2670 |
1240 |
1485 |
Studded |
||||||